Base frame
Illustrative support frame; foundations and structural design vary.
Separator / Base frame
Illustrative support frame; foundations and structural design vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Vessel shell
Hollow cylindrical enclosure with five geometric connection openings. Wall thickness, proportions and junctions are illustrative; no reinforcement, weld or pressure qualification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Dished head -1
Generic double-surface dished closure. Shape and thickness are illustrative, with no code qualification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Circumferential seam -1
Illustrates a shell-to-head seam location, without weld detail. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Dished head 1
Generic double-surface dished closure. Shape and thickness are illustrative, with no code qualification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Circumferential seam 1
Illustrates a shell-to-head seam location, without weld detail. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Saddle support -1.6
Curved saddle supports the cylindrical wall; structural design is not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Saddle foot -1.6
Illustrative attachment to a support frame. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Saddle support 1.6
Curved saddle supports the cylindrical wall; structural design is not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Saddle foot 1.6
Illustrative attachment to a support frame. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Feed nozzle fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Inlet diverter
Redirects incoming flow toward the separation zone; this plate is a conceptual arrangement. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water region
Illustrative phase volume following the vessel cross-section. Interfaces are static teaching positions, not measured levels or a flow simulation. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil region
Illustrative phase volume following the vessel cross-section. Interfaces are static teaching positions, not measured levels or a flow simulation. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas space
Illustrative phase volume following the vessel cross-section. Interfaces are static teaching positions, not measured levels or a flow simulation. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Liquid weir
Conceptual overflow weir separates the upstream settling zone from an oil collection compartment. Real arrangements vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil collection compartment
Illustrates oil collected beyond the weir; no operating level is specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Demister frame -0.48
Supports a conceptual mist-removal pack. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Demister frame 0.48
Supports a conceptual mist-removal pack. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 0 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 0 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 0 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 1 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 1 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 1 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 2 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 2 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 2 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 3 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 3 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 3 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 4 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 4 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 4 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 5 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 5 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 5 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 6 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 6 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 6 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 7 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 7 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 7 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 8 segment 0
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 8 segment 1
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Mist vane 8 segment 2
Zigzag teaching representation of a vane pack that helps collect entrained droplets. Performance and production geometry are not reproduced. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Gas outlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Oil outlet vortex breaker
A schematic plate over a liquid draw-off; real vortex-breaker design and clearance depend on duty. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Water outlet vortex breaker
A schematic plate over a liquid draw-off; real vortex-breaker design and clearance depend on duty. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Pressure instrument connection
Hollow conceptual instrument tapping through the vessel wall; no measurement, calibration or control loop is provided. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Separator / Pressure indicator
Illustrative gauge location with no numerical reading. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Base frame
Illustrative support frame; foundations and structural design vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Volute casing wall
A generic widening spiral surrounds the impeller, with a geometric discharge opening. This teaching contour is not hydraulically designed. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction-side casing cover
Encloses a side of the volute; this generic cover has a geometric central bore. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Drive-side casing cover
Encloses a side of the volute; this generic cover has a geometric central bore. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Suction inlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Discharge outlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Impeller back shroud
Back plate bounds the impeller flow passages. Thickness and contour are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Impeller front shroud
Front plate of this closed-impeller concept. Reveal internals hides it to expose the vanes. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Impeller hub
Connects the impeller assembly around the shaft. Keying and fit are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 1
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 2
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 3
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 4
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 5
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 6
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Curved impeller vane 7
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Shaft
Transfers drive rotation to the impeller. This schematic omits verified fits, fatigue and torque calculations. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Shaft key
Illustrates a keyed connection; key dimensions and stresses are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Casing wear ring
Conceptual stationary clearance ring at the suction eye. No clearance or wear limit is specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Stationary seal face
Conceptual stationary annular face in a mechanical seal. Materials and seal balance are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Rotating seal face
Conceptual rotating face adjacent to the stationary face. No leakage or temperature performance is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Seal gland
Generic gland around the shaft; seal-flush piping and cartridge design are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Seal spring 1
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Seal spring 2
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Seal spring 3
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Seal spring 4
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing outer race -0.15
Generic stationary outer bearing race, without load rating or lubrication design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing inner race -0.15
Generic shaft-side race. Bearing performance and fits are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 1
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 2
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 3
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 4
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 5
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 6
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 7
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 8
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 9
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball -0.15 / 10
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing outer race 0.35
Generic stationary outer bearing race, without load rating or lubrication design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing inner race 0.35
Generic shaft-side race. Bearing performance and fits are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 1
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 2
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 3
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 4
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 5
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 6
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 7
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 8
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 9
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing ball 0.35 / 10
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing housing
Generic bearing enclosure; lubrication passages are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Pump coupling half
Conceptual shaft coupling half; alignment tolerances and guard design are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Flexible coupling element
Generic flexible-element position between coupling halves. No elastomer specification or torque capacity. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor coupling half
Conceptual motor-side coupling half. No alignment procedure is supplied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Coupling guard
Simplified removable guard around the coupling; not a certified guarding design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor body
A generic electric drive enclosure; electrical internals are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 1
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 2
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 3
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 4
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 5
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 6
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 7
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 8
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 9
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 10
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 11
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor cooling fin 12
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor rotor marker
Simple drive rotor marker; windings, magnetic fields and speed are not modeled. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Casing foot
Illustrative low attachment beneath the casing. This foot stays clear of the impeller envelope; foundation loads are not designed. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Bearing pedestal
Supports the bearing housing beneath the shaft line. Foundation and alignment details are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil transfer pump / Motor pedestal
Supports the generic motor enclosure. Mounting feet and foundation loads are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 2
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Casing wear ring
Conceptual stationary clearance ring at the suction eye. No clearance or wear limit is specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 9
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 9
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 5
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing housing
Generic bearing enclosure; lubrication passages are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 6
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 8
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing outer race 0.35
Generic stationary outer bearing race, without load rating or lubrication design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 3
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Seal spring 1
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Stationary seal face
Conceptual stationary annular face in a mechanical seal. Materials and seal balance are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 2
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 1
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 5
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 2
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 7
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 7
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Pump coupling half
Conceptual shaft coupling half; alignment tolerances and guard design are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Shaft key
Illustrates a keyed connection; key dimensions and stresses are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 3
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Volute casing wall
A generic widening spiral surrounds the impeller, with a geometric discharge opening. This teaching contour is not hydraulically designed. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Seal gland
Generic gland around the shaft; seal-flush piping and cartridge design are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 8
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor body
A generic electric drive enclosure; electrical internals are omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 3
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 4
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 1
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Impeller front shroud
Front plate of this closed-impeller concept. Reveal internals hides it to expose the vanes. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Shaft
Transfers drive rotation to the impeller. This schematic omits verified fits, fatigue and torque calculations. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 2
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Seal spring 2
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 7
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 6
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 10
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 10
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Flexible coupling element
Generic flexible-element position between coupling halves. No elastomer specification or torque capacity. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 11
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 8
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Base frame
Illustrative support frame; foundations and structural design vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction-side casing cover
Encloses a side of the volute; this generic cover has a geometric central bore. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 1
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Impeller hub
Connects the impeller assembly around the shaft. Keying and fit are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 1
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Casing foot
Illustrative low attachment beneath the casing. This foot stays clear of the impeller envelope; foundation loads are not designed. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Impeller back shroud
Back plate bounds the impeller flow passages. Thickness and contour are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 5
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 7
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 5
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 4
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor rotor marker
Simple drive rotor marker; windings, magnetic fields and speed are not modeled. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 6
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 3
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Seal spring 3
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 4
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing outer race -0.15
Generic stationary outer bearing race, without load rating or lubrication design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball -0.15 / 6
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing pedestal
Supports the bearing housing beneath the shaft line. Foundation and alignment details are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Coupling guard
Simplified removable guard around the coupling; not a certified guarding design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Drive-side casing cover
Encloses a side of the volute; this generic cover has a geometric central bore. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 10
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing inner race -0.15
Generic shaft-side race. Bearing performance and fits are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor coupling half
Conceptual motor-side coupling half. No alignment procedure is supplied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor pedestal
Supports the generic motor enclosure. Mounting feet and foundation loads are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Discharge outlet fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Seal spring 4
Schematic spring-position marker, not a helical spring or verified face-loading design. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing inner race 0.35
Generic shaft-side race. Bearing performance and fits are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Rotating seal face
Conceptual rotating face adjacent to the stationary face. No leakage or temperature performance is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Bearing ball 0.35 / 9
Schematic rolling element; this static bearing does not simulate cage or rolling kinematics. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Motor cooling fin 12
Illustrative external cooling fin. No motor thermal rating is implied. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Suction inlet fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water transfer pump / Curved impeller vane 4
Curved teaching vane forms a passage between the shrouds. Shape, count and clearances are illustrative, without a pump curve. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Base frame
Illustrative support frame; foundations and structural design vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Tank wall
Generic atmospheric tank wall with geometric fill, withdrawal and manway openings. Thickness and dimensions are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Tank floor
Generic bottom plate. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fixed roof
Double-surface fixed cone roof with an open vent penetration. Framing, weld design, loads and emergency venting are outside this model. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Roof-to-wall joint
Illustrative joint location; no weld section or qualified connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Bottom-to-wall joint
Illustrative joint location; no weld design or inspection acceptance criteria. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Illustrative liquid
Static teaching inventory; not a measured level, capacity or product specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection
Open geometric vent connection only. Normal and emergency vent devices, vapour handling, sizing and discharge destinations are omitted; this opening is not a complete venting system. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Vent connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Fill connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Withdrawal connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway neck fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway gasket
Conceptual gasket location between neck flange and cover; material, compression and leakage performance are unspecified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Manway cover
Closed removable-cover concept. Reveal internals hides this cover for learning; the explorer is not an entry or opening procedure. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rail -0.3
Illustrative access ladder; safety systems and required dimensions omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rail 0.3
Illustrative access ladder; safety systems and required dimensions omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 0.5
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 0.8
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 1.1
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 1.4
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 1.7
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 2
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 2.3
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 2.6
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Oil storage / Ladder rung 2.9
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 1.1
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Bottom-to-wall joint
Illustrative joint location; no weld design or inspection acceptance criteria. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fixed roof
Double-surface fixed cone roof with an open vent penetration. Framing, weld design, loads and emergency venting are outside this model. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Base frame
Illustrative support frame; foundations and structural design vary. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Roof-to-wall joint
Illustrative joint location; no weld section or qualified connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 1.4
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway cover
Closed removable-cover concept. Reveal internals hides this cover for learning; the explorer is not an entry or opening procedure. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 0.5
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 2.9
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 0.8
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 1.7
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Tank floor
Generic bottom plate. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway gasket
Conceptual gasket location between neck flange and cover; material, compression and leakage performance are unspecified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rail 0.3
Illustrative access ladder; safety systems and required dimensions omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 2.3
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Tank wall
Generic atmospheric tank wall with geometric fill, withdrawal and manway openings. Thickness and dimensions are illustrative. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 8
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Fill connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Illustrative liquid
Static produced-water inventory marker, without measured level, treatment, capacity or disposal permission.
Water storage / Withdrawal connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rail -0.3
Illustrative access ladder; safety systems and required dimensions omitted. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 2
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 5
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Manway neck fastener 2
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Withdrawal connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection flange
Illustrative flange ring, with no rated facing or bolt specification. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Ladder rung 2.6
Schematic ladder rung. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Water storage / Vent connection
Open geometric vent connection only. Normal and emergency vent devices, vapour handling, sizing and discharge destinations are omitted; this opening is not a complete venting system. In this invented facility, placement and scale are teaching choices, not engineering dimensions.
Incoming connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified.
Incoming connection flange
Illustrative flange ring, with no rated facing or bolt specification.
Incoming connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection.
Incoming connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection
Hollow generic connection with illustrative wall thickness. Welds, facing and pressure ratings are not specified.
Gas handling connection flange
Illustrative flange ring, with no rated facing or bolt specification.
Gas handling connection fastener 1
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 2
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 3
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 4
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 5
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 6
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 7
Generic fastener position. Quantity and size do not specify a rated connection.
Gas handling connection fastener 8
Generic fastener position. Quantity and size do not specify a rated connection.
Route / Incoming stream to separator
Invented feed path: Incoming production stream to Three-phase separator. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Incoming stream to separator
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Route / Separated oil to transfer concept
Invented oil path: Three-phase separator to Oil transfer pump. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Separated oil to transfer concept
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Route / Oil transfer to storage concept
Invented oil path: Oil transfer pump to Oil storage concept. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Oil transfer to storage concept
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Route / Separated water to transfer concept
Invented water path: Three-phase separator to Produced-water transfer pump. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Separated water to transfer concept
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Route / Water transfer to storage concept
Invented water path: Produced-water transfer pump to Produced-water storage concept. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Water transfer to storage concept
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Route / Separated gas to the handling boundary
Invented gas path: Three-phase separator to Further gas handling — outside model. Direction is a teaching relationship, not simulated flow, a design route or an operating sequence.
Direction / Separated gas to the handling boundary
Static arrow for the declared process relationship. No velocity, quantity or live flow is represented.
Gas-route support -0.5
Illustrative elevated-route support. Loads, spacing and attachment are not specified.
Gas-route support 4.5
Illustrative elevated-route support. Loads, spacing and attachment are not specified.